4D Flow MRI Helicity Index (HI) Calculator

Clinical calculation support · Verify results before clinical use

Analysis inputs

Enter ROI measurements exported from your 4D Flow MRI post-processing workflow.

—Total HI

Whole region of interest (ROI)

Use the same volume unit for all volume fields (for example, mL or voxel count). The numerator is the volume where absolute LNH meets or exceeds the selected threshold.

A threshold of 0.60 was used in a published BAV cohort study; this is not a universal clinical cutoff.

Optional descriptive value from your post-processing software (range 0–1).

Optional aortic segment analysis

For each segment, enter both values or leave both fields blank. Segment volumes must use the same unit as the whole ROI.

Reset form

About the Helicity Index

Local normalized helicity describes the alignment between the local velocity vector and vorticity vector in a flow field. It is commonly expressed as LNH = (v · ω) / (|v||ω|), where v is velocity and ω is vorticity. Its value ranges from −1 to +1; the absolute value describes alignment magnitude without preserving rotational handedness.

Calculation used here

HI = volume where |LNH| ≥ threshold ÷ total segmented ROI volume. The result is a fraction between 0 and 1 (also shown as a percentage). This calculator does not derive LNH from raw MRI velocity data; it requires preprocessed measurements from validated 4D Flow MRI analysis software.

Workflow notes

  • Complete appropriate 4D Flow MRI preprocessing, including correction of velocity aliasing and other relevant acquisition artefacts.
  • Segment the lumen and calculate voxel-wise velocity and vorticity using an appropriate post-processing method.
  • Apply the same threshold and consistent volume units to the ROI and its subsegments.
  • Report acquisition settings, segmentation strategy, cardiac phase, and threshold alongside results to support reproducibility.

Clinical context and limitations

A published study of 65 controls and 50 patients with bicuspid aortic valve (BAV) found that absolute LNH above 0.6 differentiated groups and was associated with aortic diameter and stenosis severity. This supports the threshold as a research method in that study context, not as a universal normal range or standalone diagnostic or prognostic rule.

References

Garcia J, Barker AJ, Collins JD, Carr JC, Markl M.Volumetric quantification of absolute local normalized helicity in patients with bicuspid aortic valve and aortic dilatation. Magnetic Resonance in Medicine. 2017;78(2):689–701. DOI: 10.1002/mrm.26387; PMID: 27539068.PubMed record · Full text (PMC)
Morbiducci U, Ponzini R, Rizzo G, et al.In vivo quantification of helical blood flow in human aorta by time-resolved three-dimensional cine phase contrast magnetic resonance imaging. Annals of Biomedical Engineering. 2009;37(3):516–531. DOI: 10.1007/s10439-008-9609-6; PMID: 19142728.PubMed record
Clinical and research disclaimer: This calculator performs arithmetic on user-supplied, post-processed measurements. It is not a diagnostic instrument, does not assess raw 4D Flow MRI data, and must not be used alone to make clinical decisions. Interpret results in the context of acquisition quality, segmentation reproducibility, the study population, and the relevant scientific evidence.