P-wave Dispersion (PWD) Calculator

Clinical calculation support · Verify results before clinical use

Calculate P-wave dispersion

Enter the longest and shortest P-wave durations measured on a 12-lead ECG. Use the same units for both values.

Pmax − Pmin Formula
ms
Longest measurable P-wave duration among the ECG leads.
ms
Shortest measurable P-wave duration among the ECG leads.

About P-wave dispersion

P-wave dispersion is calculated as the difference between the longest and shortest P-wave durations measured across ECG leads: PWD = Pmax − Pmin. It has been studied as an electrocardiographic marker of heterogeneous atrial conduction and as a possible correlate of atrial fibrillation risk.

Measurement considerations

  • Measure P-wave onset and offset carefully across the ECG leads, using a consistent method.
  • Digital ECG measurement may improve precision compared with measurement on paper, but measurement methods are not fully standardized.
  • Differences in recording, lead selection, and observer identification can affect the result.

Interpreting the value

The original Dilaveris study reported that a P-wave dispersion value of 40 ms separated patients with a history of idiopathic paroxysmal AF from healthy controls in that study population (sensitivity 83%, specificity 85%). These results do not establish 40 ms as a universal diagnostic cutoff across all populations or ECG measurement methods.

References

Dilaveris PE, Gialafos EJ, Sideris SK, et al. Simple electrocardiographic markers for the prediction of paroxysmal idiopathic atrial fibrillation. American Heart Journal. 1998;135(5 Pt 1):733–738. DOI: 10.1016/S0002-8703(98)70030-4.
Magnani JW, et al. P-wave indices, distribution and quality control assessment (from the Framingham Heart Study). Annals of Noninvasive Electrocardiology. 2010;15(1):77–84. Full text.
Bayes de Luna A, et al. P Wave Parameters and Indices: A Critical Appraisal of Clinical Utility, Challenges, and Future Research. Circulation: Arrhythmia and Electrophysiology. 2022;15(4):e010435. DOI: 10.1161/CIRCEP.121.010435.
Clinical disclaimer: This calculator performs an arithmetic calculation only. P-wave dispersion is a research marker with measurement limitations and should be interpreted in the context of the ECG, clinical presentation, and other available data. It is not a stand-alone diagnostic test or a substitute for clinical judgement.