CMR Feature Tracking Dyssynchrony Index (CMR-FT DI) Calculator

Clinical calculation support · Verify results before clinical use

Calculate mechanical dyssynchrony

Enter segmental time-to-peak (TTP) strain values from the CMR feature-tracking report. Results are descriptive calculations, not a stand-alone CRT selection tool.

CMR · FT
1

Cardiac cycle

Use the RR interval corresponding to the cine acquisition and TTP measurements.

2

Segmental time-to-peak strain

Enter TTP in milliseconds for the 16-segment LV model. Blank fields are omitted; at least 3 valid values are required. Use all valid segments when available.

3

Optional: mid-ventricular radial delay

Enter mid-LV short-axis radial-strain TTP for both the anteroseptal and posterior walls to calculate the published pairwise delay measure.

Reset calculator

About CMR feature-tracking dyssynchrony

CMR feature tracking derives myocardial deformation from routine cine images. Timing-based dyssynchrony measures describe differences in when myocardial segments reach peak strain and depend on strain direction, software, acquisition, and analysis protocol.

Calculation methods

  • Segmental TTP dispersion: sample standard deviation (n−1 denominator) of the entered TTP values, reported in milliseconds.
  • RR-normalized dispersion: TTP standard deviation divided by RR interval × 100. This is a descriptive normalization, not a universally standardized or independently validated clinical index.
  • Anteroseptal–posterior radial delay: absolute difference between the two entered mid-ventricular radial-strain TTP values.

Important limitations

Onishi et al. compared mid-LV radial dyssynchrony by FT-CMR with echocardiographic speckle tracking in 72 patients. Agreement was more acceptable in patients with marked dyssynchrony; limits of agreement were approximately ±84 ms. The authors stated that clinical usefulness for predicting outcomes required further investigation. The study did not validate the 16-segment SD-of-TTP calculation here as a treatment-selection threshold.

Reference

Onishi T, Saha SK, Ludwig DR, et al.Feature tracking measurement of dyssynchrony from cardiovascular magnetic resonance cine acquisitions: comparison with echocardiographic speckle tracking. Journal of Cardiovascular Magnetic Resonance. 2013;15:95. DOI: 10.1186/1532-429X-15-95. PMID: 24134158.View PubMed record · Read full text

Clinical use

This calculator supports transparent arithmetic and research only. It does not diagnose dyssynchrony, predict CRT response, or replace guideline-based assessment integrating symptoms, LVEF, QRS morphology and duration, scar, and other clinical factors.

Clinical disclaimer: This calculator is an educational aid. Verify segment definitions, strain direction, timing convention, and software output before comparing values across patients or studies. Do not use these results in isolation to make treatment decisions.