CT-Aortic Valve Calcium (AVC) Density Calculator
Patient and CT measurements
Use the same annular area measurement convention as the method used at your institution.
ASSESSMENT
Clinical interpretation
CT aortic valve calcium scoring can help adjudicate aortic stenosis severity when echocardiographic measurements are discordant, especially in low-flow, low-gradient presentations. The Agatston score estimates calcific burden; AVC density normalizes the score to the aortic annulus area.
Thresholds implemented
- AVC density: ≥476 AU/cm2 in men and ≥292 AU/cm2 in women, based on the published sex-specific density thresholds.
- Pawade et al. absolute AVC: ≥2,065 AU in men and ≥1,274 AU in women.
- ACC/AHA 2020 absolute AVC: 2,000 AU in men and 1,300 AU in women are the sex-specific values cited for severe AS assessment.
- ESC/EACTS 2025: absolute AVC >2,000 AU in men and >1,200 AU in women indicate that severe AS is likely; higher values (>3,000 AU in men and >1,600 AU in women) make it highly likely, while lower values (<1,600 AU in men and <800 AU in women) make it unlikely.
Important limitations
These thresholds are not interchangeable, and a value near a cutoff should not be treated as a definitive binary diagnosis. Caution is needed in bicuspid aortic valves, cardiac amyloidosis, and predominantly fibrotic, post-rheumatic, radiation-associated, or inflammatory stenosis, where severe obstruction may occur without a high calcium score. The annulus area must be measured consistently with the method supporting the density threshold.
References
Clinical notes
Document key findings and keep a structured record for your own reference.
My notes
Review, edit, or remove notes saved in this browser.
Report an issue
Your feedback helps us improve the reliability and usability of this clinical tool.