PET-CT Perfusion Heterogeneity Index (PHI) Calculator
MBF heterogeneity analysis
Enter segment-level myocardial blood flow values for stress and, optionally, rest. Values must use the same segment definition and units.
RDSD / Mean
How the index is calculated
Relative dispersion (RD) describes the spread of a set of regional flow measurements relative to their mean. In this calculator, the entered values are treated as the complete set of segments being described, so population standard deviation (denominator N) is used.
| Measure | Formula | Meaning |
|---|---|---|
| Mean MBF | Σ MBF / N | Average of the entered segment values |
| Population SD | √[Σ(MBF − mean)² / N] | Absolute spread of the values |
| Relative dispersion | SD / mean | Spread relative to the mean; dimensionless |
| RD ratio | Stress RD / Rest RD | Comparison of dispersion between conditions, when defined |
| RD difference | Stress RD − Rest RD | Absolute change in relative dispersion |
Important methodological considerations
- RD depends on how the myocardium is partitioned and on the spatial resolution of the measurements; comparisons require a consistent segmentation and processing method.
- Stress and rest values should be paired by segment and derived with compatible acquisition and quantification methods.
- Image noise, motion, partial-volume effects, tracer kinetics, reconstruction, and software can affect quantitative MBF estimates.
- RD does not replace assessment of absolute MBF, myocardial flow reserve, relative perfusion images, or clinical context.
Evidence and references
Bassingthwaighte JB, King RB, Roger SA.
Fractal nature of regional myocardial blood flow heterogeneity. Circ Res. 1989;65(3):578–590. DOI: 10.1161/01.RES.65.3.578; PMID: 2766485.
PubMed record
van Beek JHGM, Roger SA, Bassingthwaighte JB.
Regional myocardial flow heterogeneity explained with fractal networks. Am J Physiol. 1989;257(5 Pt 2):H1670–H1680. DOI: 10.1152/ajpheart.1989.257.5.H1670; PMID: 2589520.
PubMed record
Schindler TH, Zhang XL, Vincenti G, et al.
Diagnostic value of PET-measured heterogeneity in myocardial blood flows during cold pressor testing for the identification of coronary vasomotor dysfunction. J Nucl Cardiol. 2007;14(5):688–697. DOI: 10.1016/j.nuclcard.2007.06.120; PMID: 17826322.
PubMed record
Sciagrà R, Lubberink M, Hyafil F, et al.; EANM Cardiovascular Committee.
EANM procedural guidelines for PET/CT quantitative myocardial perfusion imaging. Eur J Nucl Med Mol Imaging. 2021;48:1040–1069. DOI: 10.1007/s00259-020-05046-9; PMID: 33135093.
PubMed record · Full text
Clinical disclaimer: This calculator provides descriptive statistics for user-entered MBF values. It is not a validated diagnostic or prognostic score, and it does not establish the presence, mechanism, or severity of ischemia or coronary microvascular dysfunction. Do not use the numerical output as the sole basis for clinical decisions. Verify the source data, segment mapping, image quality, and quantification method before interpretation.
PERSONAL WORKSPACE
Clinical notes
Document key findings and keep a structured record for your own reference.
Private by design. Notes are stored in this browser on this device only. They are not uploaded to Appcardio.
Export or share this note
PERSONAL WORKSPACE
My notes
Review, edit, or remove notes saved in this browser.
Stored locally on this device
QUALITY & SAFETY
Report an issue
Your feedback helps us improve the reliability and usability of this clinical tool.
Please describe the issue clearly. For calculation concerns, include the input values and expected result where possible.