RV-PA Coupling (Ees/Ea) Surrogate Index Calculator
Coupling assessment
Select a method and enter the available measurements.
| Parameter | Value | Method / note |
|---|---|---|
| No calculation yet. | ||
This index supports clinical assessment and must not be used in isolation.
Clinical context
Right ventricular–pulmonary arterial (RV–PA) coupling describes how well RV contractility adapts to pulmonary vascular load. Pressure–volume analysis is the reference approach; TAPSE/PASP is a practical echocardiographic surrogate.
Echocardiographic surrogate: TAPSE/PASP
TAPSE/PASP = TAPSE (mm) ÷ PASP (mmHg), reported in mm/mmHg. In severe PAH or CTEPH, a value below 0.31 mm/mmHg discriminated RV–PA uncoupling defined by invasive Ees/Ea <0.805. This threshold is population- and context-dependent, not universal.
Invasive single-beat estimate
- Ees = (Pmax − ESP) / SV
- Ea = ESP / SV
- Ees/Ea = (Pmax − ESP) / ESP = (Pmax / ESP) − 1
Ees and Ea are reported in mmHg/mL; Ees/Ea is dimensionless. The single-beat approach depends on waveform analysis and simplifying assumptions. The mPAP-based ESP regression is a method-specific estimate.
Interpretation and limitations
Ees/Ea <0.805 defined uncoupling in the cited severe PH validation study. Values above it are not necessarily normal or optimal. For TAPSE/PASP, <0.31 is supported in severe PH cohorts. A 0.31–0.35 “borderline” band is not a universal validated category.
This calculator does not estimate mortality or replace right-heart catheterization, expert waveform review, or full clinical assessment.
References
Clinical notes
Document key findings and keep a structured record for your own reference.
My notes
Review, edit, or remove notes saved in this browser.
Report an issue
Your feedback helps us improve the reliability and usability of this clinical tool.