HeartLogic Multisensor Algorithm (Approximate Calculator)

Clinical calculation support · Verify results before clinical use

Multisensor Trend Explorer

Compare patient-specific baseline and current sensor values.

—Trend index
This educational tool calculates a transparent illustrative trend index. It does not reproduce the proprietary HeartLogic algorithm and cannot determine a device alert state.

S3 amplitude

Unit: device units. An increase is treated as a worsening-direction trend in this illustrative model.

S1 amplitude

Unit: device units. A decrease is treated as a worsening-direction trend in this illustrative model.

Thoracic impedance

Unit: ohms. A decrease is treated as a worsening-direction trend in this illustrative model.

Respiratory rate

Unit: breaths/min. An increase is treated as a worsening-direction trend in this illustrative model.

Night heart rate

Unit: bpm. An increase is treated as a worsening-direction trend in this illustrative model.

Activity

Unit: minutes/day. A decrease is treated as a worsening-direction trend in this illustrative model.

About the HeartLogic Multisensor Algorithm

HeartLogic is a proprietary device diagnostic available in selected Boston Scientific ICD and CRT-D systems. It combines trends from device-based sensors, including first and third heart sounds, thoracic impedance, respiration, nocturnal heart rate, and activity, into a composite index.

The device index is calculated daily using changes relative to historical patient-specific baselines. This page does not reproduce internal signal processing, weighting, normalization, sensor fusion, or alert recovery logic.

What this tool does

  • Calculates relative changes for entered baseline/current sensor pairs.
  • Maps selected trend directions to illustrative 0–1 contributions using arbitrary scales and weights.
  • Combines available contributions into a 0–100 exploratory index for education only.

Important limitations

  • Input units and acquisition methods may differ from device report values.
  • Simple percent changes do not reproduce device filtering or moving baselines.
  • Percent change is undefined when baseline equals zero; that sensor is excluded from the composite calculation.
  • The exploratory index has no validated clinical cutoffs, risk categories, or prognostic calibration.

Clinical context and references

In the MultiSENSE validation study, the proprietary device algorithm at its nominal threshold of 16 had 70% sensitivity and a median lead time of 34 days before heart failure events. These findings do not validate this approximation.

Boehmer JP, Hariharan R, Devecchi FG, et al.A multisensor algorithm predicts heart failure events in patients with implanted devices: Results from the MultiSENSE study. JACC: Heart Failure. 2017;5(3):216–225. DOI: 10.1016/j.jchf.2016.12.011. PMID: 28254128.
Gardner RS, Singh JP, Stancak B, et al.HeartLogic multisensor algorithm identifies patients during periods of significantly increased risk of heart failure events: Results from the MultiSENSE study. Circulation: Heart Failure. 2018;11(7):e004669. DOI: 10.1161/CIRCHEARTFAILURE.117.004669. PMID: 30002113.
Boston Scientific.HeartLogic Alert Management Guide and Physician’s Technical Guide. Official HeartLogic resources.
Clinical disclaimer: This is an educational exploratory calculator, not a medical device, validated prediction model, or substitute for the manufacturer’s HeartLogic Index. Do not use its result for patient-level diagnosis, alert classification, treatment decisions, or risk prediction. Review the device-generated report and interpret it with symptoms, examination, and standard clinical assessment.