Cardiac Power Output Index (CPO Index) Calculator
Hemodynamic calculation
Enter cardiac power output and body surface area (BSA) to calculate the indexed value.
About the Cardiac Power Index
Cardiac power output (CPO) integrates pressure and forward flow as an estimate of the hydraulic power delivered by the heart. The indexed measure, commonly called the cardiac power index (CPI), adjusts CPO for body surface area.
Formula
| Measure | Formula | Unit |
|---|---|---|
| Cardiac power output (CPO) | MAP × cardiac output ÷ 451 | W |
| Cardiac power index (CPI) | CPO ÷ BSA | W/m² |
| Equivalent indexed form | MAP × cardiac index ÷ 451 | W/m² |
In the conventional formula, MAP is mean arterial pressure in mmHg, cardiac output is in L/min, and 451 is the conversion constant used in the cited clinical literature. Cardiac index is cardiac output divided by BSA.
Reference range and clinical use
A resting CPI around 0.5–0.7 W/m² is commonly cited for a well-compensated adult. Lower cardiac power measurements have been associated with worse outcomes in cohorts with cardiogenic shock and acute cardiac disease, but prognostic thresholds depend on the parameter, population, and measurement context.
- CPI and CPO are not interchangeable; CPI is indexed to BSA.
- The reported CPO threshold of 0.53 W in the SHOCK registry refers to unindexed CPO, not CPI.
- Use serial trends alongside clinical examination and other hemodynamic data rather than interpreting a single number in isolation.
References
Clinical notes
Document key findings and keep a structured record for your own reference.