HbA1c Estimated Glucose Calculator

Clinical calculation support · Verify results before clinical use

Enter laboratory HbA1c

Use the HbA1c result reported by the laboratory, in percent.

Enter a value between 2% and 25%. This broad input range is intended to catch data-entry errors and is not a diagnostic or normal reference range.

How the calculation works

HbA1c reflects glycation of hemoglobin during red blood cell circulation and is commonly used to assess longer-term glycemic exposure. The ADAG study related laboratory HbA1c to mean glucose measured using continuous glucose monitoring and structured self-monitoring.

eAG (mg/dL) = 28.7 × HbA1c (%) − 46.7

Clinical interpretation

The result can help communicate HbA1c in units similar to home glucose meters. It should be considered alongside actual glucose measurements, symptoms, treatment, and the clinical situation. eAG is not a separate diagnostic test and does not establish a diagnosis by itself.

Important limitations

  • Hemolysis, recent blood loss, transfusion, and other changes in red blood cell turnover can affect HbA1c interpretation.
  • Iron deficiency and some hemoglobin variants may alter the result; assay-specific interference can vary.
  • When HbA1c does not match measured glucose or the clinical picture, consider the cause and use appropriate alternative glycemic assessment when indicated.

Reference

Nathan DM, Kuenen J, Borg R, et al.; A1c-Derived Average Glucose Study Group. Translating the A1C Assay Into Estimated Average Glucose Values. Diabetes Care. 2008;31(8):1473–1478. DOI: 10.2337/dc08-0545 · PMID: 18540046
National Glycohemoglobin Standardization Program (NGSP). Factors that Interfere with HbA1c Test Results. Updated June 23, 2026. Official NGSP guidance
Clinical disclaimer: This calculator is intended for educational and clinical support. It does not replace laboratory interpretation, direct glucose monitoring, or clinician judgement. Do not use the estimated value alone to make treatment changes.