Systemic Vascular Resistance Index (SVRi) Calculator

Clinical calculation support · Verify results before clinical use

Hemodynamic inputs

Enter measured values to calculate the systemic vascular resistance index.

80Factor

Use the measured or calculated mean systemic arterial pressure.

mmHg

Use a right atrial pressure value obtained using an appropriate hemodynamic method.

mmHg

Cardiac output indexed to body surface area; this is not cardiac output.

L/min/m2

Formula and clinical context

Systemic vascular resistance index (SVRi or SVRI) estimates systemic vascular resistance adjusted for body surface area. When cardiac index is used, the indexed formula is:

ParameterFormula / unit
SVRi(MAP − RAP) × 80 ÷ CI
MAPMean arterial pressure, mmHg
RAPRight atrial pressure, mmHg
CICardiac index, L/min/m²
SVRi unitsdyn·s·cm⁻⁵·m²

Reference interval

Published reference intervals differ. The PICU Handbook lists 800–1600 dyn·s·cm⁻⁵·m², while other critical-care references report higher intervals, including approximately 1970–2390. These values should not be treated as universally interchangeable; use the interval appropriate to the patient population, measurement method, and local laboratory or hemodynamic protocol.

Clinical interpretation

SVRi should be interpreted together with blood pressure, cardiac index, filling pressures, perfusion, lactate, and the clinical context. Changes in the ratio do not necessarily represent changes in vascular tone alone. Do not use this calculation in isolation to select or titrate vasoactive treatment.

References

Cardiovascular Formulas and Parameters.The PICU Handbook, Chapter 27. Provides SVR/SVRI formula and an SVRI reference interval of 800–1600 dyn·s·cm⁻⁵·m². Publisher reference.
Hemodynamic monitoring — Surgical Treatment.NCBI Bookshelf. Reports SVRI formula and reference values of 1760–2600 dyn·s·cm⁻⁵·m². NCBI Bookshelf.
Normal Values for Cardiac Index and Related Measurements.Merck Manual Professional Edition. Provides reference context for cardiac index and systemic resistance measurements. Merck Manual.
Clinical disclaimer: This calculator is intended for educational and clinical reference use by qualified healthcare professionals. Hemodynamic measurements are method-dependent and can be affected by clinical state, ventilation, vasoactive medications, and measurement error. Confirm units and values, apply local protocols, and do not use the calculated value as the sole basis for clinical decisions.