Pulmonary Artery Pulsatility Index (PAPi) Calculator
Calculate the pulmonary artery pulsatility index (PAPi) from invasive pulmonary artery and right atrial pressure measurements. Select a clinical context to view a population-specific reference threshold.
Hemodynamic Parameters
Enter pressure values obtained during the same hemodynamic assessment.
PAPi Result
Select a clinical context to review its reference threshold.
About PAPi
The pulmonary artery pulsatility index (PAPi) is an invasive hemodynamic index calculated as pulmonary artery pulse pressure divided by right atrial pressure. It combines pulmonary artery pulsatility with right-sided filling pressure and is used as an adjunctive marker when assessing right ventricular function and right-sided hemodynamics.
Calculation
PAPi = (PASP − PADP) / RAP
- PASP: pulmonary artery systolic pressure (mmHg).
- PADP: pulmonary artery diastolic pressure (mmHg).
- RAP: mean right atrial pressure (mmHg).
Because numerator and denominator are expressed in the same pressure unit, PAPi is a dimensionless ratio.
Population-Specific Thresholds
| Clinical population | Threshold reported | Evidence context |
|---|---|---|
| Acute inferior MI with suspected RV dysfunction | ≤0.9 | ROC-derived cutoff in the original small derivation study |
| Cardiogenic shock / RV shock | <1.0 | Hemodynamic criterion listed in AHA/ACC/HFSA guidance |
| After LVAD implantation risk assessment | <1.85 | Reported in LVAD cohorts and AHA scientific statement |
These thresholds are not interchangeable and should not be applied to an unrelated population without supporting evidence.
Measurement Considerations
- Use invasive pulmonary artery and right atrial pressure measurements obtained under comparable hemodynamic conditions.
- Ensure all pressure values are expressed in mmHg and refer to the same assessment period.
- Interpret PAPi alongside the clinical examination, echocardiography, cardiac output/index, filling pressures, and the underlying disease state.
- Changes in loading conditions, vasoactive or inotropic support, mechanical ventilation, and mechanical circulatory support may affect hemodynamic interpretation.