OASIS Score Calculator for ICU Mortality

Clinical calculation support · Verify results before clinical use

ICU First-Day Assessment

Enter the patient's worst relevant observations during the first 24 hours after ICU admission.

—OASIS

OASIS uses ten clinical and admission variables. Record the minimum and maximum values observed during the first ICU day where requested. All fields are required to avoid silently treating missing observations as normal.

01

Demographics and pre-ICU stay

Patient age and elapsed hospital time before ICU admission.

Time from hospital admission to ICU admission. Enter 0 for direct admission.
02

Neurological status

Lowest total Glasgow Coma Scale score during the first 24 hours.

03

Heart rate

Minimum and maximum heart rate during the first 24 hours.

04

Mean arterial pressure

Minimum and maximum MAP during the first 24 hours.

05

Respiratory rate

Minimum and maximum respiratory rate during the first 24 hours.

06

Body temperature

Minimum and maximum temperature during the first 24 hours.

Enter all available first-day readings separated by commas. This preserves the OASIS temperature bands, which are not monotonic.
07

Urine output

Total urine output over the first 24 hours in the ICU.

08

Mechanical ventilation

Any mechanical ventilation during the first 24 hours in ICU.

09

Elective surgery status

Elective surgery classification used by the OASIS scoring implementation.

—Total score
Estimated in-hospital mortality probability
Complete all fields to calculate
The mortality estimate will appear here.

The probability is generated by the original OASIS logistic model. It is a cohort-derived estimate, not an individualized certainty and not a treatment threshold.

ComponentPoints
No calculation yet.

About the OASIS Score

The Oxford Acute Severity of Illness Score (OASIS) is an ICU severity-of-illness score developed to support risk adjustment and prediction of in-hospital mortality using a reduced set of routinely collected clinical variables. It does not require laboratory measurements, diagnostic codes, or comorbidity data.

The score is calculated from ten components using data from the first 24 hours of the ICU stay: age, pre-ICU hospital length of stay, Glasgow Coma Scale, heart rate, mean arterial pressure, respiratory rate, temperature, urine output, mechanical ventilation, and elective surgery status.

Mortality probability equation

p = 1 / [1 + exp(−(−6.1746 + 0.1275 × OASIS))]

This is the original score-based logistic model for estimated in-hospital mortality. No low-, intermediate-, or high-risk bands are imposed here because a universally accepted bedside category threshold was not established in the sources used for this implementation.

Important application notes

  • Use the first 24 hours after ICU admission, not an arbitrary later observation window.
  • For physiological variables with repeated measurements, use the worst relevant values (the component score is determined by the most adverse qualifying observation).
  • Urine output is the total volume over the 24-hour period, in mL.
  • Enter actual measured values. Do not assume that an undocumented or missing value is normal.
  • OASIS is a prognostic severity score and should not be used alone to make treatment-limitation, triage, or discharge decisions.

Component scoring reference

ComponentCriterionPoints
Age (years)<24 / 24–53 / 54–77 / 78–89 / >890 / 3 / 6 / 9 / 7
Pre-ICU LOS (hours)<0.17 / 0.17–<4.95 / 4.95–24 / >24–311.8 / >311.85 / 3 / 0 / 2 / 1
GCS15 / 14 / 8–13 / 3–70 / 3 / 4 / 10
Heart rate (beats/min)33–88 / >88–106 / >106–125 / <33 / >1250 / 1 / 3 / 4 / 6
MAP (mmHg)61.33–143.44 / 51–<61.33 / 20.65–<51 or >143.44 / <20.650 / 2 / 3 / 4
Respiratory rate (/min)13–22 / 6–12 or 23–30 / >30–44 / >44 / <60 / 1 / 6 / 9 / 10
Temperature (°C)36.40–36.88 / 35.94–<36.40 or >36.88–39.88 / <33.22 / 33.22–<35.94 / >39.880 / 2 / 3 / 4 / 6
Urine output (mL/24 h)2544–6896 / 1427–<2544 / 671–<1427 / >6896 / <6710 / 1 / 5 / 8 / 10
Mechanical ventilationNo / Yes0 / 9
Elective surgery statusElective / Urgent or emergency0 / 6

References

Johnson AEW, Kramer AA, Clifford GD.A new severity of illness scale using a subset of acute physiology and chronic health evaluation data elements shows comparable predictive accuracy. Critical Care Medicine. 2013;41(7):1711–1718. DOI: 10.1097/CCM.0b013e31828a24fe.
El-Manzalawy Y, et al.OASIS+: leveraging machine learning to improve the prognostic accuracy of OASIS severity score for predicting in-hospital mortality. BMC Medical Informatics and Decision Making. 2021;21:156. DOI: 10.1186/s12911-021-01517-7. Used as a secondary source describing the OASIS components and probability equation.
MIT Laboratory for Computational Physiology. MIMIC Code Repository.OASIS score implementation (MIMIC-IV). Source code. Used to cross-check scoring cut-points and mortality probability implementation.
Johnson AEW. OASIS project and reference code.Original developer resource and code implementations. OASIS project page · Code repository.
Clinical disclaimer: OASIS is a severity-of-illness and prognostic instrument developed from specific ICU cohorts. Its predicted probability may be miscalibrated when applied to different populations, hospitals, case mixes, or contemporary treatment settings. It must not replace clinical assessment or be used as the sole basis for triage, escalation, withdrawal of treatment, or other patient-care decisions.