Fick Cardiac Output Calculator

Clinical calculation support · Verify results before clinical use

Hemodynamic inputs

Enter the patient's body surface area, hemoglobin, and arterial/mixed venous oxygen saturations.

VO2Estimated
m2
Enter BSA in square metres. Input validation range: 0.2–3.5 m2.
g/dL
Use the measured hemoglobin concentration.
%
Enter saturation as a percentage from 0 to 100.
%
For mixed venous saturation, use a sample representative of pulmonary arterial blood when clinically indicated.

Calculation method and clinical context

The Fick principle relates systemic blood flow to oxygen consumption divided by the arterial–mixed venous oxygen content difference. This page estimates oxygen consumption from body surface area, so it calculates an indirect (assumed-VO2) Fick cardiac output, not direct Fick cardiac output.

Equations used

Estimated VO2125 mL/min/m2 × BSA (m2)
Arteriovenous O2 difference1.34 × Hb (g/dL) × [SaO2 − SvO2] × 10, with saturations expressed as fractions; result in mL O2/L.
Cardiac outputVO2 (mL/min) ÷ arteriovenous O2 content difference (mL O2/L)
Cardiac indexCardiac output (L/min) ÷ BSA (m2)

Interpretation and limitations

Cardiac output must be interpreted alongside the clinical state and other hemodynamic measurements. A value outside a commonly expected adult range does not, by itself, establish a diagnosis or determine treatment.

  • Estimated VO2 may differ substantially from measured oxygen consumption, which can produce clinically important error in the indirect Fick estimate.
  • When precise invasive hemodynamics are required, direct Fick measurement with measured VO2 or an appropriate alternative method should be considered according to the clinical setting.
  • In suspected intracardiac shunting or unexpectedly high mixed venous saturation, stepwise oxygen saturation assessment may be necessary.
  • Sampling, hemoglobin, saturation measurement, steady-state conditions, and method assumptions all affect reliability.

References

Humbert M, Kovacs G, Hoeper MM, et al.2022 ESC/ERS Guidelines for the diagnosis and treatment of pulmonary hypertension. European Heart Journal. 2022;43(38):3618–3731.doi:10.1093/eurheartj/ehac237
StatPearls Publishing.Calculating FICK Cardiac Output and Input. NCBI Bookshelf.NCBI Bookshelf chapter
The contemporary pulmonary artery catheter review.The contemporary pulmonary artery catheter. Part 2: measurements, limitations, and clinical applications.Full text at PubMed Central
Clinical disclaimer: This calculator is intended for educational and clinical decision support and does not replace direct hemodynamic assessment or professional judgment. It uses assumed oxygen consumption and should not be treated as equivalent to direct Fick measurement. Confirm inputs and interpret results in the context of the patient, sampling conditions, and relevant guidelines.