30-Day Readmission Risk Score After TAVR Calculator
Clinical risk factor review
Select the documented findings to support post-discharge planning after transcatheter aortic valve replacement (TAVR).
Clinical context
A published risk score for early unplanned readmission was derived from 10,345 patients who underwent contemporary self-expanding TAVR at 350 centers in the STS/ACC TVT Registry during 2015–2017. The reported 30-day unplanned readmission rate was 9.2%.
The study identified the clinical and procedural factors listed in this checklist. Its reported low- and high-risk groups had readmission rates of 5.8% and 14.6%, respectively. Those rates apply to the study's score-defined groups and must not be assigned from this checklist's factor count.
Factors assessed
| Domain | Factor reported in the study |
|---|---|
| Comorbidity | Diabetes mellitus; atrial fibrillation |
| Clinical status | Advanced heart failure symptoms; home oxygen use; reduced 5-m gait speed or inability to walk |
| Renal function | Serum creatinine >1.6 mg/dL |
| Hospital course | Index length of stay >5 days |
| Procedure / valve function | Major vascular complication; at least moderate post-procedure aortic or mitral regurgitation |
Reference
Scope and limitations
The published study focused on contemporary self-expanding TAVR in a United States registry. Performance in other valve platforms, populations, and healthcare systems is not established by the abstract alone.
The publicly accessible abstract confirms predictors and observed risk-group rates but does not provide enough detail to reconstruct and independently verify every point weight and total-score threshold. The original file's illustrative weights are therefore not represented as the published model.
Clinical notes
Document key findings and keep a structured record for your own reference.
My notes
Review, edit, or remove notes saved in this browser.
Report an issue
Your feedback helps us improve the reliability and usability of this clinical tool.