Catheter Ablation Success Predictor (APPLE & SUCCESS)

Clinical calculation support · Verify results before clinical use

Patient characteristics

Enter pre-ablation clinical and echocardiographic variables. The APPLE score updates automatically.

0APPLE score
One point for age strictly greater than 65 years.
Persistent AF includes long-standing persistent AF.
One point for eGFR below 60.
One point for diameter ≥43 mm.
One point for LVEF below 50%.
Used only for the unvalidated exploratory tally shown below; it is not part of the original APPLE score.

Risk score results

Scores support counseling and do not determine individual outcomes.

—APPLE / 5
APPLE recurrence risk category
Complete all required fields
Enter patient data to calculate the APPLE score.
Clinical interpretation

The APPLE score estimates the risk of atrial arrhythmia recurrence after AF catheter ablation. It is not a measure of procedural safety or a guarantee of success.

Prior-ablation adjusted tally (exploratory only)

Complete all required fields to display APPLE score plus the number of prior ablations. This arithmetic tally is not presented as a validated SUCCESS score and has no validated risk categories.

APPLE categories used here: 0 = low, 1–2 = intermediate, and ≥3 = high recurrence risk. These are qualitative strata, not calibrated individual probabilities.

About the APPLE score

The APPLE score was developed to predict rhythm outcome after catheter ablation of atrial fibrillation. It assigns one point for each of five baseline features. Higher scores were associated with a greater frequency of recurrence in the derivation and validation cohorts.

Variables and points

VariableCriterionPoints
Age>65 years+1
AF typePersistent or long-standing persistent+1
Renal functioneGFR <60 mL/min/1.73 m²+1
Left atrial diameter≥43 mm+1
LVEF<50%+1

Score interpretation

APPLE scoreCategoryInterpretation
0LowLower observed recurrence risk compared with higher scores.
1–2IntermediateIntermediate recurrence risk stratum.
3–5HighHigher observed recurrence risk; not a calibrated probability.

Important model distinction

The original code described “SUCCESS” as APPLE plus one point per prior ablation. The cited evidence available for this review supports APPLE and its evaluation in repeat-ablation cohorts, but does not establish that this arithmetic extension is a validated model named SUCCESS. The extension is therefore displayed only as an exploratory tally, without risk classification or clinical recommendation.

References

Kornej J, et al.

The APPLE score: a novel and simple score for the prediction of rhythm outcomes after catheter ablation of atrial fibrillation. Clinical Research in Cardiology. 2015;104:871–876.

doi:10.1007/s00392-015-0856-x
Kornej J, et al.

The APPLE Score – A Novel Score for the Prediction of Rhythm Outcomes after Repeat Catheter Ablation of Atrial Fibrillation. PLoS ONE. 2017;12(1):e0169933.

doi:10.1371/journal.pone.0169933
Clinical disclaimer: This tool is intended to support, not replace, clinical assessment and shared decision-making. The APPLE score has modest discrimination in published cohorts and should not be used as the sole basis for selecting ablation, determining procedural strategy, or setting follow-up. Interpret results in the context of AF phenotype, comorbidities, atrial substrate, ablation strategy, rhythm-monitoring intensity, and patient preferences.