DETECT Algorithm (for Systemic Sclerosis)
Step 1 — Non-Echocardiographic Assessment
Calculate the published DETECT risk points to determine whether echocardiography is recommended.
About the DETECT Algorithm
The DETECT algorithm is a two-step screening strategy developed specifically to improve early detection of pulmonary arterial hypertension in patients with systemic sclerosis.
Step 1 uses six non-echocardiographic variables: FVC/DLCO ratio, current or past telangiectasias, anti-centromere antibody, NT-proBNP, serum urate, and ECG right axis deviation.
A Step 1 total risk score >300 points leads to echocardiography. Step 2 incorporates the carried-forward Step 1 score together with right atrial area and TR velocity. A Step 2 total risk score >35 points leads to referral for right heart catheterization.
In the original DETECT study, the algorithm had approximately 96% sensitivity, 48% specificity, 35% positive predictive value, and 98% negative predictive value in the study population.
Primary reference
Coghlan JG, Denton CP, Grünig E, et al.
Evidence-based detection of pulmonary arterial hypertension
in systemic sclerosis: the DETECT study.
Ann Rheum Dis. 2014;73(7):1340–1349.
Guideline reference
Humbert M, Kovacs G, Hoeper MM, et al.
2022 ESC/ERS Guidelines for the diagnosis and treatment
of pulmonary hypertension.
Eur Heart J. 2022;43(38):3618–3731.
Clinical notes
Document key findings and keep a structured record for your own reference.
My notes
Review, edit, or remove notes saved in this browser.
Report an issue
Your feedback helps us improve the reliability and usability of this clinical tool.