Device Safety in Contact Sports Index (ICD Pacemaker Risks) Calculator

Clinical calculation support · Verify results before clinical use

Clinical assessment inputs

Complete each item to structure a discussion. This index has not been clinically validated.

—Index points
01

Select the implanted cardiac electronic device.

02

Examples are illustrative; assess the actual sport and impact mechanics.

03

Enter a non-negative number of weeks.

04

For pacemaker-only devices, this item is not applicable; interpret the response carefully.

05

Determine from device interrogation and clinical assessment.

06

Consider indication, intensity, and sport-specific bleeding exposure.

07

Broad categories do not replace disease-specific risk assessment.

08

Do not count S-ICD electrodes or leadless devices as transvenous leads.

—Points
Heuristic index category
Complete all fields
The index will be calculated when all required fields are completed.
Clinical next step

Do not use this unvalidated score to grant or deny sports clearance. Arrange individualized assessment with the treating electrophysiology/sports-cardiology team.

The point weights and bands are unvalidated. This score does not estimate a probability of injury, arrhythmia, device failure, or death.

How to interpret this index

This tool retains the source code’s rule-based point assignments as a discussion aid. It is not a published or validated prediction instrument, and its categories are not guideline-defined eligibility classes.

Scoring items retained from source code

DomainPoint assignment
Sport contactNon-contact 0; limited-contact +2; collision +4
Device typeTransvenous ICD +2; transvenous pacemaker +2; leadless pacemaker +1; S-ICD 0
Time since implant<6 weeks +4; 6 to <12 weeks +2; ≥12 weeks 0
Appropriate ICD shock in prior 12 monthsYes +3
Pacemaker dependentYes +3
AnticoagulationYes +2
DiagnosisCardiomyopathy +2; channelopathy +1; other 0
Transvenous lead burden1 lead +1; ≥2 leads +2; none 0

Original heuristic bands

0–3: lower; 4–7: intermediate; ≥8: higher heuristic concern. These bands are retained for transparency only. The theoretical maximum is 22 points, not 16 as stated in the original output.

Important factors not fully captured

  • Sport intensity, collision mechanics, and likelihood of direct impact to generator or leads.
  • Device model, pocket location, lead integrity, interrogation findings, programming, and exercise-related sensing/therapy behavior.
  • Reason for ICD implantation, current arrhythmia control, symptoms, ventricular function, and disease-specific exercise recommendations.
  • Anticoagulant indication, bleeding risk, athlete preferences, emergency action plan, and access to prompt defibrillation.

Evidence and references

Lampert R, et al. 2024 HRS Expert Consensus Statement on Arrhythmias in the Athlete: Evaluation, Treatment, and Return to Play.Heart Rhythm. 2024;21(10):e151–e252. Emphasizes individualized disease-specific assessment, shared decision-making, emergency planning, and considering sport type when selecting/programming devices. DOI: 10.1016/j.hrthm.2024.05.018. PubMed record.
Lampert R, et al. Safety of Sports for Athletes With Implantable Cardioverter-Defibrillators: Results of a Prospective, Multinational Registry.Circulation. 2013;127:2021–2030. Registry evidence informs discussion but does not validate this index or establish collision-sport safety for every device configuration. DOI: 10.1161/CIRCULATIONAHA.112.000447; PubMed record.

Practical checklist

  • Confirm device function and healing with the implanting team.
  • Review recent therapies, symptoms, diagnosis, and exercise-specific risk.
  • Discuss device/lead protection and direct chest-impact risk.
  • Agree on an emergency action plan with rapid AED access and trained responders.
  • Use shared decision-making with electrophysiology and sports-cardiology expertise.
Clinical disclaimer: Educational support only. This tool is not prospectively validated and must not independently determine sports eligibility or treatment. The 2024 HRS consensus recommends sport-aware device considerations and individualized assessment; evidence remains limited for collision-sport trauma across device systems. Confirm decisions with the treating team and current guidance.