ECG Basic – P Wave
ECG Basic: P Wave
Understand the P wave as the surface ECG expression of atrial depolarisation. Learn its normal appearance, how to measure it, and how changes in morphology can point toward atrial enlargement or a non-sinus rhythm.
Learning objectives
What does the P wave represent?
The P wave is the ECG waveform generated by atrial depolarisation. In sinus rhythm, the electrical impulse begins in the sinoatrial node and spreads through the atrial myocardium before reaching the atrioventricular (AV) conduction system.
On a typical ECG, the P wave precedes the QRS complex. Its appearance is not identical in every lead: the direction of the recorded deflection depends on the relationship between the atrial electrical vector and the lead axis. A P wave may therefore be upright, negative, or biphasic in different leads.
Normal sinus P-wave characteristics
Assess the P wave in more than one lead. Lead II is useful for overall morphology, while V1 often reveals the separate contributions of right and left atrial activation.
| Feature | Expected sinus P-wave finding | Practical interpretation |
|---|---|---|
| Morphology | Smooth contour; usually monophasic in lead II; typically biphasic in V1. | Compare the shape across leads rather than relying on a single lead. |
| Axis / polarity | Usually upright in leads I and II and inverted in aVR; axis approximately 0° to +75°. | Unexpected inferior-lead inversion should prompt consideration of a non-sinus atrial activation sequence. |
| Duration | Less than 120 ms (less than 3 small squares at 25 mm/s). | Measure from the earliest onset to the latest offset of the P wave. |
| Amplitude | Less than 2.5 mm in limb leads and less than 1.5 mm in precordial leads. | Measure from the isoelectric baseline to the peak or trough. |
How the atrial waveforms form the P wave
Atrial activation is sequential. The right atrium is activated before the left atrium, and the electrical forces generated by both chambers combine to produce the surface P wave.
- The first portion of the P wave predominantly reflects right atrial activation.
- The final portion predominantly reflects left atrial activation.
- The middle portion contains overlapping electrical contributions from both atria.
- In lead II, the two components generally point in a similar direction, producing a single upright waveform.
- In V1, the components may point in opposite directions, creating a biphasic P wave: an initial positive component followed by a terminal negative component.
ECG patterns associated with atrial enlargement
The supplied reference describes characteristic P-wave changes associated with right atrial enlargement (RAE), left atrial enlargement (LAE), and biatrial enlargement. These are ECG patterns; interpret them in the context of the full tracing and clinical assessment.
Right atrial enlargement pattern
In lead II, the P wave becomes taller, classically described as P pulmonale.
- Lead II: peaked P wave with amplitude greater than 2.5 mm.
- Duration may remain below 120 ms in the pattern described by the source.
- V1: increased height of the initial positive component, greater than 1.5 mm.
Left atrial enlargement pattern
In lead II, the P wave may become broad and notched, classically described as P mitrale.
- Lead II: duration greater than 120 ms; a notch may be present but is not obligatory.
- V1: terminal negative component wider than 40 ms and deeper than 1 mm.
- Overall P-wave height in lead II may remain within normal limits.
Lead II and V1: pattern comparison
| Pattern | Lead II | Lead V1 |
|---|---|---|
| Typical | Smooth, upright, usually monophasic; duration under 120 ms and amplitude under 2.5 mm. | Biphasic, with positive and negative components of broadly similar size. |
| RAE pattern | Tall, peaked P wave; amplitude greater than 2.5 mm. | Initial positive component greater than 1.5 mm. |
| LAE pattern | Broad P wave, duration greater than 120 ms; notching may occur. | Terminal negative component wider than 40 ms and deeper than 1 mm. |
| Biatrial pattern | Features suggesting both right- and left-sided atrial abnormality may coexist. | Both an increased initial positive component and an abnormal terminal negative component may be present. |
Other important P-wave abnormalities
Inverted P waves
Inversion of P waves in the inferior leads (II, III, and aVF) suggests that atrial activation is not proceeding in the usual sinus direction. The relationship to the PR interval can help narrow the likely origin, as described in the supplied reference:
| Finding | Possible site of origin | Example |
|---|---|---|
| Inverted P waves in inferior leads with PR interval less than 120 ms | AV junction | Accelerated junctional rhythm |
| Inverted P waves in inferior leads with PR interval 120 ms or longer | Atrial focus | Ectopic atrial rhythm |
Variable P-wave morphology
Different P-wave shapes within the same ECG may reflect more than one atrial activation focus. The supplied reference uses the following distinction:
- Multifocal atrial rhythm: at least three distinct P-wave morphologies.
- Multifocal atrial tachycardia (MAT): at least three distinct P-wave morphologies with an atrial rate of 100 beats/min or higher.
A practical approach to P-wave assessment
- Find the P waves. Inspect a rhythm strip and the 12-lead ECG; use lead II and V1 as key starting points.
- Assess the relationship to QRS complexes. Determine whether P waves precede QRS complexes consistently and whether the relationship is plausible for the rhythm.
- Check polarity. In sinus rhythm, P waves are usually upright in I and II and negative in aVR.
- Measure duration and amplitude. Compare measurements with the normal values in the table above, accounting for ECG calibration.
- Inspect morphology in lead II and V1. Look for a tall peaked contour, a broad/notched contour, or an abnormal terminal negative component.
- Consider a non-sinus origin when appropriate. Inferior-lead inversion or changing P-wave shapes should prompt a closer rhythm analysis.
- Integrate the result. Describe the ECG finding, avoid overcalling anatomy from morphology alone, and correlate with the wider clinical picture.
Measurement reminder at standard paper speed
At 25 mm/s, one small horizontal square represents 40 ms and three small squares represent 120 ms. Vertically, 10 mm corresponds to 1 mV when standard gain is 10 mm/mV; therefore 1 mm represents 0.1 mV.
Knowledge check
Choose the best answer for each question, then select Check answers.
Key takeaways
- The P wave represents atrial depolarisation.
- A typical sinus P wave is smooth, upright in leads I and II, negative in aVR, and often biphasic in V1.
- Normal duration is less than 120 ms; amplitude is less than 2.5 mm in limb leads and less than 1.5 mm in precordial leads, according to the supplied reference.
- Lead II and V1 are particularly useful when assessing atrial morphology.
- A tall, peaked P wave suggests a right atrial enlargement pattern; a broad, notched or prolonged P wave suggests a left atrial enlargement pattern.
- Inferior-lead P-wave inversion and variable P-wave morphologies can indicate non-sinus atrial activation.
- Always interpret P-wave findings alongside the complete ECG and clinical context.
References and further reading
Continue learning
Clinical notes
Document key findings and keep a structured record for your own reference.
My notes
Review, edit, or remove notes saved in this browser.
Report an issue
Your feedback helps us improve the reliability and usability of this clinical tool.