ECG Basic – PR Interval
PR Interval
Understand how to measure the PR interval, recognize normal and abnormal values, and use a short or prolonged PR interval to guide ECG interpretation.
Learning objectives
1. What is the PR interval?
The PR interval is measured from the first deflection of the P wave to the first deflection of the QRS complex. It represents the time required for an electrical impulse to travel from the onset of atrial depolarization until the onset of ventricular depolarization. This includes conduction through the atria, AV node, and His–Purkinje system.
2. Normal PR interval
In adults, the normal PR interval is generally 120–200 milliseconds (0.12–0.20 seconds), equivalent to approximately three to five small ECG squares at a paper speed of 25 mm/s.
How to measure
- Identify a lead in which the onset of the P wave and QRS complex are clearly visible. Lead II is often useful.
- Mark the earliest beginning of the P wave, then identify the earliest beginning of the QRS complex.
- Count the small squares between these two points and multiply by 40 ms at 25 mm/s.
- Measure several representative beats when the rhythm or conduction varies; report the pattern as well as the value.
4. Prolonged PR interval (>200 ms)
A PR interval longer than 200 ms indicates delayed atrioventricular conduction. When every atrial impulse is conducted to the ventricles and the PR interval remains prolonged, the ECG pattern is classified as first-degree AV block.
First-degree AV block
- PR interval is greater than 200 ms.
- Each P wave is followed by a QRS complex (1:1 AV conduction).
- The PR interval is prolonged but remains essentially constant from beat to beat.
PR prolongation with second-degree AV block
A prolonged PR interval can also be seen in second-degree AV block. In Mobitz I (Wenckebach), the PR interval progressively lengthens over consecutive conducted beats until a P wave is not followed by a QRS complex; after the pause, the sequence starts again with a shorter PR interval.
5. Short PR interval (<120 ms)
A PR interval shorter than 120 ms may occur when ventricular activation begins earlier than expected through an accessory pathway, or when the atrial impulse originates close to the AV node or His region, as can occur with a junctional rhythm.
Pre-excitation pattern
In Wolff–Parkinson–White (WPW) pattern, an accessory atrioventricular pathway activates part of the ventricle early. The classic resting ECG combination is a short PR interval, a delta wave (slurred initial QRS upstroke), and a widened QRS complex.
Short PR + delta wave + wide QRSJunctional rhythm
A junctional rhythm originates in or near the AV junction. P waves may be absent, occur before the QRS with a short PR interval, or appear after the QRS when atrial activation is retrograde.
Absent or retrograde P wavesPre-excitation: recognizing the WPW pattern
Accessory pathway conduction can provide the substrate for atrioventricular re-entrant tachycardia (AVRT). Patients may present with episodes of paroxysmal supraventricular tachycardia.
Lown–Ganong–Levine (LGL) terminology
The supplied reference describes the historical LGL pattern as a very short PR interval with normal P-wave morphology, a normal-width QRS, and no delta wave. This label is included to reflect the source material; a short PR with a narrow QRS should not, by itself, be taken as proof of a discrete accessory pathway or a definitive contemporary syndrome diagnosis.
6. Junctional rhythm and the PR interval
In a junctional rhythm, the impulse arises from the AV junction rather than the sinus node. Atrial activation may occur retrogradely, producing inverted P waves in leads where sinus P waves are normally upright. Depending on the timing of atrial activation relative to ventricular activation, the P wave may be close to, hidden within, or follow the QRS complex.
- Before the QRS: a retrograde P wave may produce a short PR interval.
- Within the QRS: atrial activity may be obscured and the P wave may not be identifiable.
- After the QRS: an inverted retrograde P wave may follow the ventricular complex.
7. Practical interpretation framework
| PR finding | Common ECG association | What to assess next |
|---|---|---|
| 120–200 ms | Within the usual adult reference range | Rhythm, P-wave morphology, and AV conduction pattern |
| >200 ms, constant | First-degree AV block when every P conducts | Symptoms, medications, QRS width, and associated conduction disease |
| Progressively lengthening | Mobitz I pattern when followed by a non-conducted P wave | Sequence of PR intervals and dropped ventricular response |
| <120 ms with delta wave | Ventricular pre-excitation (e.g., WPW pattern) | QRS width, delta wave, symptoms, and tachyarrhythmia history |
| <120 ms with altered/absent P | May occur in junctional rhythm | P-wave timing and polarity in multiple leads |
Common pitfalls
- Measuring from the peak of the P wave instead of its onset.
- Ending the measurement at the R-wave peak rather than the first onset of the QRS.
- Confusing the PR segment with the full PR interval.
- Interpreting a single PR measurement without checking for dropped beats or changing conduction.
- Diagnosing pre-excitation from a short PR interval without assessing QRS morphology.
8. Key takeaways
- The PR interval extends from the onset of the P wave to the onset of the QRS complex.
- The usual adult reference range is 120–200 ms (three to five small squares at 25 mm/s).
- A constant PR interval >200 ms with 1:1 AV conduction is the pattern of first-degree AV block.
- Progressive PR lengthening followed by a non-conducted P wave suggests Mobitz I AV block.
- A PR interval <120 ms should prompt assessment for pre-excitation or a junctional rhythm; interpret the P wave and QRS morphology together.
References
Related ECG Academy lessons
Continue with the ECG components that help complete rhythm and conduction assessment.