Pulmonary Vascular Resistance (PVR) Estimate Calculator
Estimate pulmonary vascular resistance
Enter peak tricuspid regurgitation velocity and RVOT velocity-time integral measured by Doppler echocardiography.
Enter measurements to calculate
This Doppler-derived estimate is an adjunct to comprehensive echocardiographic assessment. It does not replace right-heart catheterization when definitive hemodynamic measurement is required.
Method and clinical interpretation
This simplified echocardiographic method estimates pulmonary vascular resistance from the ratio of peak tricuspid regurgitation velocity to the RVOT time-velocity integral.
The calculator implements the simplified equation proposed by Abbas and colleagues. Their regression equation also included an intercept of 0.16 WU; the simplified equation above omits that intercept.
Interpret the ratio cautiously
- A TRV/VTIRVOT ratio below 0.20 was associated with a low likelihood of PVR above 2 WU in the original study; this is not a stand-alone exclusion test.
- TRV and VTIRVOT depend on Doppler signal quality and alignment. Recheck acquisition and measurements if the result is unexpected.
- This estimate has important limitations and should not be treated as interchangeable with invasive PVR from right-heart catheterization.
Important limitations
The original derivation study was small (44 patients). It noted limitations in patients with moderate or severe tricuspid regurgitation, congenital heart disease, shunts, and pulmonary artery dilation; applicability in these settings requires caution.
Measurement checklist
- Confirm TRV in m/s and RVOT VTI in cm.
- Ensure appropriate Doppler beam alignment and a reliable TR envelope.
- Confirm that the RVOT VTI trace is technically adequate.
- Interpret alongside the clinical context, other echocardiographic findings, and the possibility of altered flow or filling pressures.