RV-PA Coupling (Ees/Ea) Surrogate Index Calculator

Clinical calculation support · Verify results before clinical use

Coupling assessment

Select a method and enter the available measurements.

—Index
Calculator mode
Echocardiographic measurements
Tricuspid annular plane systolic excursion.
Estimated systolic pulmonary artery pressure.
Invasive pressure and flow measurements
Used to estimate ESP only when ESP is not entered.
Enter measured/derived ESP if available.
Derived from the RV pressure waveform.
Use a consistent validated measurement method.

If ESP is not entered, ESP is estimated as 1.65 × mPAP − 7.79 mmHg. This regression is method-specific and is not a substitute for measured end-systolic pressure in every patient.

—Index
Calculated result
Enter measurements
The result and interpretation will appear here after valid inputs are provided.
ParameterValueMethod / note
No calculation yet.

This index supports clinical assessment and must not be used in isolation.

Clinical context

Right ventricular–pulmonary arterial (RV–PA) coupling describes how well RV contractility adapts to pulmonary vascular load. Pressure–volume analysis is the reference approach; TAPSE/PASP is a practical echocardiographic surrogate.

Echocardiographic surrogate: TAPSE/PASP

TAPSE/PASP = TAPSE (mm) ÷ PASP (mmHg), reported in mm/mmHg. In severe PAH or CTEPH, a value below 0.31 mm/mmHg discriminated RV–PA uncoupling defined by invasive Ees/Ea <0.805. This threshold is population- and context-dependent, not universal.

Invasive single-beat estimate

  • Ees = (Pmax − ESP) / SV
  • Ea = ESP / SV
  • Ees/Ea = (Pmax − ESP) / ESP = (Pmax / ESP) − 1

Ees and Ea are reported in mmHg/mL; Ees/Ea is dimensionless. The single-beat approach depends on waveform analysis and simplifying assumptions. The mPAP-based ESP regression is a method-specific estimate.

Interpretation and limitations

Ees/Ea <0.805 defined uncoupling in the cited severe PH validation study. Values above it are not necessarily normal or optimal. For TAPSE/PASP, <0.31 is supported in severe PH cohorts. A 0.31–0.35 “borderline” band is not a universal validated category.

This calculator does not estimate mortality or replace right-heart catheterization, expert waveform review, or full clinical assessment.

References

Tello K, Wan J, Dalmer A, et al.Validation of the Tricuspid Annular Plane Systolic Excursion/Systolic Pulmonary Artery Pressure Ratio for the Assessment of Right Ventricular-Arterial Coupling in Severe Pulmonary Hypertension. Circ Cardiovasc Imaging. 2019;12(9):e009047.doi:10.1161/CIRCIMAGING.119.009047 · PMID: 31500448
Defining end-systolic pressure for single-beat estimation of right ventricle–pulmonary artery coupling: simple… but not really.ERJ Open Research. 2021;7(3):00219-2021. Discusses assumptions and limitations of ESP estimation.doi:10.1183/23120541.00219-2021
Clinical disclaimer: Educational decision-support only. Results depend on measurement quality and method assumptions and are not a stand-alone diagnostic or prognostic instrument. Interpret alongside clinical state, imaging, hemodynamics, and specialist guidance.