TRANSFORM-HF randomized 2,859 patients hospitalized with heart failure, regardless of ejection fraction, to a torsemide or furosemide treatment strategy. The figures below are observed trial-group outcomes, not individualized predictions.
Selected 12-month outcomes
| Outcome | Torsemide | Furosemide | Effect estimate |
|---|---|---|---|
| All-cause mortality | 26.1% | 26.2% | HR 1.02 (95% CI 0.89–1.18) |
| Death or all-cause hospitalization | 47.3% | 49.3% | HR 0.92 (95% CI 0.83–1.02) |
| Total hospitalizations | 940 | 987 | Rate ratio 0.94 (95% CI 0.84–1.07) |
Clinical interpretation
TRANSFORM-HF compared post-discharge loop-diuretic strategies in a pragmatic, open-label randomized trial. Its primary mortality result was neutral; the confidence interval includes both possible benefit and possible harm.
What these results mean
- The observed mortality proportions were very similar between randomized groups.
- The primary outcome did not establish a mortality advantage for torsemide over furosemide.
- Secondary estimates also had confidence intervals that included no difference.
- Diuretic selection should be individualized to clinical response, congestion, renal function, dose, adherence, availability, and clinician judgement—not to an unvalidated mortality estimate.
Important limitation
The supplied original code included a logistic equation with coefficients described as an approximation, plus a modeled 5% torsemide adjustment. The source code did not provide a validated derivation, calibration, discrimination, or external validation for that equation. Those calculations have therefore not been retained as patient-level risk estimates.