TSP Angle-Success Correlation Index Calculator

Clinical calculation support · Verify results before clinical use

Procedure details

Record the measured angle and procedure type. This tool does not calculate a probability of procedural success.

°Angle record
Enter the angle as measured in your imaging or procedural workflow. Confirm the anatomical reference and imaging projection before documenting the value.Accepted numeric range: 0–180°. The range is an input-validation boundary, not a clinical cutoff.
Select the planned or completed electrophysiology procedure.

Clinical context and limitations

Transseptal puncture planning relies on the patient’s anatomy and the imaging/projection used to visualize the interatrial septum. An angle reported as a right anterior oblique (RAO) fluoroscopic projection is not necessarily the same measurement as the inclination of a sheath trajectory relative to the septal plane. These definitions should not be conflated.

How to use this tool

  • Enter a measured angle only when its definition, reference plane, and imaging projection are known.
  • Choose the procedure type to keep the measurement record clinically contextualized.
  • Use procedural imaging and operator assessment to guide transseptal access. This page does not provide a validated risk score, success probability, or treatment recommendation.

Evidence audit summary

The source code originally assigned fixed baseline success probabilities to PVI, CTI, and AT ablation, then multiplied them by arbitrary angle-based adjustment factors. The submitted file did not provide derivation data, a regression equation, a validation cohort, calibration metrics, or sufficient evidence to support these numerical estimates. Those estimates and the labels “high/moderate/low success” have therefore been removed rather than presented as clinically validated.

The source file’s proposed universal “optimal” angle of 40–50° and thresholds at 30°/60° could not be verified as a validated predictor of ablation success. Published work on TSP angle may measure a specific anatomical orientation or fluoroscopic projection and should not be repurposed as a success-probability model without validation.

References

Lu et al. The efficiency and safety of multidetector computed tomography-guided transseptal puncture during atrial fibrillation catheter ablation.Journal of Arrhythmia. 2024. This study evaluated individualized RAO projection based on septal orientation and procedural safety; it did not validate the angle multipliers or procedure-specific success probabilities used in the original calculator. https://doi.org/10.1002/joa3.12975 · PubMed PMID: 38333397
Source references supplied in the original file: Kottkamp et al. (2021), Tokuda et al. (2020), and Rillig et al. (2022).The cited titles and bibliographic details were not independently verified as supporting the claimed 40–50° optimum or the success-probability formula. They are not retained as evidence for a predictive algorithm.
Clinical disclaimer: This tool is for measurement documentation and educational context only. It is not a validated clinical prediction instrument and must not be used to estimate procedural success, select patients, determine puncture location, or replace imaging-guided procedural judgment.