QUICKI Insulin Sensitivity Index Calculator
Fasting measurements
Enter fasting glucose and insulin measured from the same fasting assessment.
About QUICKI
The Quantitative Insulin Sensitivity Check Index (QUICKI) is a fasting-based surrogate measure developed for research assessment of insulin sensitivity. It uses fasting plasma glucose and fasting insulin concentrations.
QUICKI = 1 / [log₁₀(fasting insulin) + log₁₀(fasting glucose)]
For this implementation, glucose must be entered in mg/dL and insulin in µIU/mL. The index is dimensionless. The original method uses base-10 logarithms; natural logarithms would produce a different, incorrect result.
Understanding the result
- Higher QUICKI values generally indicate greater insulin sensitivity.
- Lower values generally indicate lower insulin sensitivity, but there is no single universal clinical cutoff for all populations and assays.
- QUICKI is a surrogate measure and does not replace a hyperinsulinemic-euglycemic clamp when a direct reference method is required.
Clinical limitations
- Use appropriately collected fasting measurements and confirm units before entering results.
- Insulin assay variability and population differences can affect interpretation.
- Do not use QUICKI alone to diagnose diabetes, prediabetes, or an individual patient's insulin resistance.
- The reference range of approximately 0.33–0.45 stated in the original page is not a universally validated reference interval; it is therefore not presented as a definitive normal range here.
Primary reference
Katz A, Nambi SS, Mather K, et al.
Quantitative insulin sensitivity check index: a simple, accurate method for assessing insulin sensitivity in humans. J Clin Endocrinol Metab. 2000;85(7):2402–2410. DOI: 10.1210/jcem.85.7.6661; PMID: 10902785.
Endotext. Assessing Insulin Sensitivity and Resistance in Humans.
Overview of fasting surrogate indices, units, equations, and limitations. NCBI Bookshelf.
Clinical disclaimer: This calculator provides a mathematical estimate from user-entered fasting measurements and is intended to support education and research. It is not a diagnosis or a substitute for clinical assessment. Confirm laboratory units and interpret results using appropriate clinical context and validated local methods.
PERSONAL WORKSPACE
Clinical notes
Document key findings and keep a structured record for your own reference.
Private by design. Notes are stored in this browser on this device only. They are not uploaded to Appcardio.
Export or share this note
PERSONAL WORKSPACE
My notes
Review, edit, or remove notes saved in this browser.
Stored locally on this device
QUALITY & SAFETY
Report an issue
Your feedback helps us improve the reliability and usability of this clinical tool.
Please describe the issue clearly. For calculation concerns, include the input values and expected result where possible.